Data Catalog searches returning incomplete or missing data

If you have a transformation that contains the Catalog Input, Catalog Output, Read Metadata, or Write Metadata steps, there may be instances when a complete search of the records in Data Catalog is not performed. This error can occur if:

The default limit provided to prevent PDI from exceeding memory limits or stop connection timeouts to PDC is too short for your environment.

To resolve this issue:

  1. Design your transformation.

  2. Right-click on the canvas to open the Transformation properties dialog box.

  3. In the Parameters tab, add the following parameter:

    catalog-result-limit

  4. In the Default Value column, enter a number greater than the default value of 25, for example 500.

  5. Run your transformation.

Note: The behavior of this parameter does not directly control the records received from Data Catalog, but rather it works to limit the sub-queries used to retrieve those records. Therefore, you may need to make additional adjustments to establish the correct limit for your environment.